STANDARD FIRE TEST FOR BULKHEADS

STANDARD FIRE TEST IS ONE IN WHICH SPECIMEN OF THE RELEVANT BULKHEAD OR DECKS ARE EXPOSED IN A TEST FURNACE TO TEMPERATURE CORRESPONDING APPROXIMATELY TO THE STANDARD TIME TEMPERATURE CURVE. THE SPECIMEN SHALL HAVE AN EXPOSED SURFACE OF NOT LESS THAN 4.65 M2  AND HEIGHT ( OR LENGTH OF DECK) OF 2.44 M, RESEMBLING AS CLOSELY AS POSSIBLE THE INTENDED CONSTRUCTION AND INCLUDING WHERE APPROPRIATE AT LEAST ONE JOINT. THE STANDARD TIME TEMPERATURE CURVE IS DEFINED BY A SMOOTH CURVE DRAWN THROUGH THE FOLLOWING TEMPERATURE POINTS MEASURED ABOVE THE INITIAL FURNACE TEMPERATURE

AT THE END OF THE FIRST                             5 MINUTES             556 DEGREE CELSIUS

AT THE END OF THE FIRST                             10 MINUTES           659 DEGREE CELSIUS

AT THE END OF THE FIRST                              15MINUTES           718 DEGREE CELSIUS

AT THE END OF THE FIRST                              30MINUTES           821 DEGREE CELSIUS

AT THE END OF THE FIRST                               60 MINUTES          925 DEGREE CELSIUS